Site Supervisor

Site Supervisor Facility Control

Unleashing the power of connected controls

Site Supervisor maximizes your visibility and control over key refrigeration applications. With Site Supervisor, you can consider your store monitoring challenges solved.

Copeland Presence in Cold Chain Market

Across the Cold Chain, Copeland Is Supporting Customers To Solve Their Critical Problems And Help Improve Their Operations, Performance & Food Safety. Our Broad Portfolio Of Solutions Caters To Each Node In The Cold Chain

Testimonials

Site Supervisor Hardware: Overview

  • 3 Ethernet Ports (1 Eth0 & 2 Eth1)
  • On-board I/O
    • 8 Analog Inputs
    • 4 Digital Inputs
    • 4 Relay outputs (for alarm)
  • 4 Serial port connection
    • Serial 1,2, 3, & 4 are fully configurable for I/O, Modbus, and Display.
  • 1 Can Bus port (communication – expansion modules)
  • 2 USB port
  • With MicroSD slot

Site Supervisor: Key Attributes

Technical Specifications

Operating Temperature14°F to 140°F (-10°C to 60°C)
Relative Humidity20-85% RH non-condensing
Enclosure RatingUL 94 V-0
Dimensions110mm x 183mm
(4 5/16” x 7 3/16”)
24 VAC20VA required 24VAC/20VA
1 Can BusExpansion Module Connections
4 RS485 portsMODBUS Com Ports 1, 2, 3, 4
3 Ethernet PortsPorts 1, 1, 0
Analog Inputs8
2 USB Inputs1, 2
MicroSD1
Digital Inputs4
Relay Outputs4
Agency ApprovalsULE211299, CE

Site Supervisor Device and Connections

Site Supervisor Device and Connections

Site Supervisor Unit

  • Small size allows easy installation and retrofit, even in existing panels
  • Digital, analog, relay and serial connectors support wide variety of equipment and communication types
  • USB and micro SD storage
  • Increase capability through expansion boards
  • Rugged:  Use in a broad range of environmental conditions
  • Connect and control with desktop and mobile interfaces
  • Daily store-level or enterprise operation requires no maintenance
Read More...
Site Supervisor Device and Connections

Site Supervisor Wiring Diagram

The wiring diagram gives a detailed overview on the hardware connections, thus providing our customers with ease of installation and user-friendly experience!

Read More...
Site Supervisor Wiring Diagram
Site Supervisor Wiring Diagram

Site Supervisor Application Matrix
APPLICATIONSMFRXBXCX
Max Devices32199199199
Log Group12323232
Digital Combiner64128128128
Time Schedule8646464
AHU6066
Lighting602424
Analog Sensor Control12646464
Digital Sensor Control12645464
Flexible Combiner64128128128
Standard Circuit663016
Suction Groups*0402
Enhanced Suction Group*0402
Condenser0101


SMF = Small supermarkets/ C-stores / Discount

BX = QSRs

CX/CXe = Supermarkets/Hypermarkets

*The number of suction groups allowed is in total for both types. That is the RX only allows 4 total whether they are Standard, Enhanced, or a mix of both

Centralized Management

Real Time Monitoring

Energy Consumption Analysis

Advisory Map & Floor Plan

Advisory Notification

Maintenance Management

Smart Connect – WeChat App

Documents & Drawings

Please enable JavaScript to use this website.