Refrigerant Leak Detection System (RLDS)
High Precision Refrigerant Monitor
Emerson’s RLDS delivers the best refrigerant monitoring available, with industry-leading MDL (minimum detectable level) of 1 ppm for halogenated gases, the fastest sampling frequency and the widest range of refrigerants accurately detected. The large graphic LCD display and LED status indicators provide a system-wide overview at a glance.
The RLDS enhances effective refrigerant management, detecting leaks early to enable cost savings by reducing refrigerant discharge, enhancing energy effi ciency and reducing risk of refrigeration failure and product loss. A variety of communication interfaces are available, including Modbus, BACnet and LonWorks, allowing easy integration into BMS systems and remote monitoring solutions.
MEASUREMENT | UNIT | DESCRIPTION |
Gas Library | RLDS | CFC: R11, R12, R113, R114, R502, HFP HFC: R125, R134a, R236FA, R245Fa, R32, R404a, R407a, R407c, R-407F, R410a, R422a, R422d, R427a, R507, R508b HCFC: R123, R124, R21, R22, R227, R23, R401a, R402a, R402b, R408a, R409a, R500, R503 Halon: H1211, H1301, H2402 Other: FA188, FC72, H1234YF, H1234ZE, N1230, N7100, N7200, N7300, N7600, R424A, R426A, R438A, CUSTOM |
RLDS CO2 | CO2/R744 | |
Measuring Range | RLDS | All gases 0 to 10,000 ppm |
RLDS CO2 | CO2 0 to 8,000 ppm | |
Accuracy | RLDS | 1 ppm MDL (most gases) +1ppm +10% of reading from 0-1,000 ppm (most gases) +1ppm +2% of reading with fi eld calibration (most gases) +10ppm +15% of reading from 0-1,000 ppm (R-11, R-21, R32) |
RLDS CO2 | +5 ppm +5% of reading from 0-1,000 ppm +10% of reading from 1,000-4,000 ppm +15% of reading from 4,000-8,000 ppm | |
Temperature | RLDS | +0.8% (R134a) of reading per OC between purge cycles |
SPECIFICATION | DESCRIPTION |
Coverage | Zones: 4,8,12 and 16 zone systems available |
Sensor | Proprietary non-dispersive infrared (NDIR) technology |
Dimensions | 12.23”H x 13.7” x 4.96 (21.0642 cm x 34.7980 cm x 12.5984 cm) |
Weight | 15 lbs (6.8 kg) |
User Interface | Front Panel with 3 Indicator Lights: • Green = Monitor is powered on. LED glows during normal operation; fl ashes when unit is in warm-up mode • Red = Alarm. LED fl ashes when any point has exceeded the alarm setting • Yellow = Fault. LED fl ashes when there is a system fault |
Communications | Full two-way communication with BMS via RS-485 serial interface. RS-232C communication port standard. |
Alarms | Four SPDT alarm contacts are provided rated 2A at 250 VAC (inductive), 5A at 250 VAC (resistive).Three assigned to ppm level alarms, one assigned to system faults. |
Conditioned Signal | Optional dual 4-20mA DC isolated outputs. Channel 1 = zone area, Channel 2 = ppm |
System Noise | Less than 40dB(A) @ 10 feet (3 meters) |
Response Time | 5 to 315 seconds – depending on air line length and number of zones |
Sampling Mode | Automatic or manual (hold) |
Monitoring Distance | 1200 ft max (500 ft for NH3) for combined length of sample and exhaust tubing (each zone) |
Power Safety Mode | Fully automatic system reset. All programmed parameters retained. |
Operating Temperature | 32°F to 122°F (0°C to 50°C) |
Ambient Humidity | 5% to 90% RH non-condensing |
Altitude Limit | 6,562 ft (2,000 m) |
Power | 100 to 240 VAC, 50/60 Hz, 20W |
Approvals | UL 61010-14, CAN/CA 22.2 No. 61010-1; EN61010-1, EN61326; EN14624; CE Mark |
PART # | DESCRIPTION |
808-2004 | RLDS 4 Zone |
808-2005 | RLDS 4 Zone, w/HHT & Gateway |
808-2008 | RLDS 8 Zone |
808-2009 | RLDS 8 Zone, w/HHT & Gateway |
808-2012 | RLDS 12 Zone |
808-2013 | RLDS 12 Zone, w/HHT & Gateway |
808-2016 | RLDS 16 Zone |
808-2017 | RLDS 16 Zone, w/HHT & Gateway |
808-2104 | RLDS CO2 4 Zone |
808-2105 | RLDS CO2 4 Zone, w/HHT & Gateway |
808-2108 | RLDS CO2 8 Zone |
808-2109 | RLDS CO2 8 Zone, w/HHT & Gateway |
808-2112 | RLDS CO2 12 Zone |
808-2113 | RLDS CO2 12 Zone, w/HHT & Gateway |
808-2116 | RLDS CO2 16 Zone |
808-2117 | RLDS CO2 16 Zone, w/HHT & Gateway |