High Efficiencies With Low Environmental Impacts

At a time when legacy hydrofluorocarbon (HFC) refrigerants are being phased out due to their high global warming potential (GWP), R-290 has emerged as an increasingly viable low-GWP alternative. With excellent thermodynamic properties — such as low back pressure, high volumetric capacity and coefficient of performance (COP) — R-290 delivers excellent energy efficiencies compared to HFCs.


With a GWP of 3 and an ozone depletion potential (ODP) of 0, R-290 poses virtually no threat to the environment. Current U.S. safety standards limit refrigeration system charges to 150g.

Read More...
Click to continue reading High Efficiencies With Low Environmental Impacts
refrigeration charge limits

Increasing R-290 Charge Limits Expand Its Potential

Because R-290 is classified as an A3 (flammable) refrigerant, the governing bodies that regulate the safe use of refrigerants in the U.S. have established a 150g maximum charge limit — making R-290 an ideal refrigerant for a wide variety of smaller, self-contained coolers and freezers.

Increasing R-290 charge limits above 150g would expand its potential applications in commercial refrigeration even further. A recent update to the Underwriters Laboratories’ (UL) second edition of its UL 60335-2-89 standard paves the way for higher R-290 charge limits.

Read More...
Click to continue reading Increasing R-290 Charge Limits Expand Its Potential

Equipment Safety Drives R-290 Adoption

Modern refrigeration technologies have evolved to ensure equipment safety and support the use of R-290 in an expanding range of applications. Today, R-290 is primarily used in small, self-contained, reach-in display cases, beverage coolers, frozen drink machines, ice machines and ice cream freezers — all which feature a built-in condensing unit.

For more than a decade, Copeland has been producing R-290 rated compressors and condensing units to support self-contained refrigeration original equipment manufacturers (OEMs).

Read More...
Click to continue reading Equipment Safety Drives R-290 Adoption
R290 Equipment

R-290 FAQs

What class of refrigerant is R-290?
Is R-290 a good refrigerant?
Is the R-290 refrigerant dangerous?
Which refrigerant is better: R-134A or R-290?
What is the R-290 charge limit in refrigeration?
What safety precautions are required to use R-290?
What does “highly flammable” mean?
What causes A3s to ignite?
Read More...
Click to continue reading R-290 FAQs
Please enable JavaScript to use this website.